Top Fuse                         ture  measuring  papers  should  logue indicators might have tem-
                                              be used; those heat sensitive pa-
                                                                              perature reading tolerances be-
                                              pers  should  be  placed  between  tween +-15 C. In such cases; the
             APPLICATIONS                     the cloth and the fusible interlin-  thermometer might close the
             AND GENERAL                      ing while they are going into the  circuit at 135 degrees Celsius,
             SUGGESTIONS                      press. Temperature is measured  whereas it ought to do so at 150
                                              by the darkening rate of the heat  degrees Celsius, and may mislead
                                              indicators  on  the  paper.  If  this  the operator.
                                              process is applied to the right and   •There should not be any corro-
                                              left wings of the press at the same  sion allowed on the press cylin-
                                              time, it allows observing whether  ders, and the cylindrical pressure
                                              heat  differences  occur  between  should be equally balanced on
                                              wings, or not.                  left, right and middle parts.
                                                                               •The cylinders should be checked
                                              PRESS PROPERTIES                frequently, the silicone covered
             During  the  application,  the  coat                             cylinders must be changed regu-
             on the fusible interlining is liquid-  •To keep the quality at standards,  larly and the hardness of the sili-
             ized by using heat, and the trans-  the  maintenance  of  the press  cone should be controlled contin-
             fer of this liquid onto the cloth at   should be made regularly and on  uously.
             necessary amount is established   time.                          •The operators should be experi-
             by the pressure. At the end of this   •It should be used in an environ-  enced.
             process,  by  the  cooling  and  the   ment which is isolated from the  •For  the presses  operating  with
             solidification  of  the  coat,  perfect   flow of yarn and fibre, and humid-  single personnel; as the blankets
             fusing  of  the  cloth  and  the  fusi-  ity.                    may erode unequally, the person-
             bleinterlining is established.    •It should have the structure and  nel should work in rotation.
             In the application of fusible inter-  properties that are matching with  •Products that come out of the
             lining adhesion, the safest way is   the purpose.                press should not be handled be-
             to use a press machine. The qual-  •The heat and pressure values  fore they are cooled, and in case
             ity and the well-kept state of the   should be homogenous on the  of necessity for handling hot, ap-
             press  is  one  of  the  most  impor-  surface of the press blanket.  propriate  care  should  be given.
             tant factors that directly affect the    •The similarity of the parameter  Otherwise, finger marks and loos-
             final quality of the shirt. Although   indicators (pressure and heat)  en strength occurs at the points of
             the type of fusible interlining may   and actual indicators should  contact.
             differ  with  regard  to  the  cloth   be checked frequently, in case  •There should not be any deep
             quality  to  be  applied,  there  are   of mismatching occasions, the  scratches or patches on the blan-
             some  general  criteria  about  the   maintenance should be informed  ket surface. If there are patches,
             usage of the presses. Press tem-  for the necessary fixing.      care must be given to make the
             perature should be around:       •The parameter indicators should  fusing of cloth and fusible inter-
             •  160  degrees  Celsius  for  fusi-  be  sensitive  enough.  Some  ana-  lining apart from this patchy area.
             bleinterlining  products  that  are
             100 g/m  or below,
                     2
             • 170 degrees Celsius for fusible
             interlining  products  that  are  be-
             tween 100 g/m  and 130g/m
                                      2
                           2
             • 175 degrees Celsius for fusible
             interlining  products  that  are  130
                 2
             g/m  or above. To control the sug-
             gested  temperature,  tempera-
   1   2   3   4   5   6   7   8