CLOTH SPREADING thorn apart, if the dispersion of •If the effusion is over the fusible
the coating powder remained on interlining, reduce the tempera-
The spread part should be free of the base cloth is not homoge- ture of the press upper resist-
humidity. If the cloth of the fusible neous, then the press cylinders ance.
interlining is laid for a long time might have corroded.
after spreading, high humidity of • Decrease the pressure.
them may cause negative effects. • Do the fusing application in dif-
In such cases, firstly by com- ferent parts of the press. If you • Increase the speed.
pressing separately, the humid- end in varied results, contact with
ity should be removed. With this the press machine manufacturer 4. Bad fusing and bad handle af-
method, the cloths have a sort or the technical service. ter the application
of sanforizing even they have not
been finished as so. 2. Bowing because of shrinkage •In this case, it means that, be-
cause of the over heat and the low
BONDING QUALITY • Compress the cloth. Check the pressure, the coat was separated
CONTROL AND LAST shrinkage difference with anoth- from the fusible interlining but
IRON er cloth, cut in the same dimen- was not transferred to the cloth
sions. successfully. Thus, the coat be-
At the testing stage, do not go comes a hard layer between the
into the bulk production with- •If there is no problem with the cloth and the interlining and with-
out checking the dismantle- cloth, fuse the interlining with out fusing to the cloth, it worsens
ment strength. The detachment the compressed cloth, and check the handle.
strength after fusing, for the cloth the shrinkage difference with an-
and fusible interlining, cut and other interlining, cut in the same 5.If risings occur on the shirt after
fused as 5cm width stripes should dimensions. If the shrinkage washing then it means
ast 1.2kg. During dismantlement, against heat exceeds the stand-
remember that some portion of ards, contact to the related per- •The press compression is low;
the coat of the fusible interlin- son from the help desk. coat transfer is not at the ade-
ing must remain on the contrary quate level.
applied cloth. Do not exceed the 3. Effusion of the coat over the
temperature of 160 degrees Cel- cloth or fusible interlining •The press speed is too high and
sius while ironing the shirt as the fusing is not reliable.
approaching to the melting tem- • If the effusion is over the cloth,
perature of the coat may risk reduce the temperature of the •The press temperature is too
the fusing application. Wash the press lower resistance. low and the fusing is not reliable.
fused shirts 5 times at 90 degrees
Celsius and check whether there • After that decrease the pres- •The interlining coat level is low
is pilling on the surface of adhe- sure and increase the speed. and the fusing is not reliable.
sion or not.
POSSIBLE PROBLEMS
DURING APPLICATION
AND
TROUBLESHOOTING
1. If the fusing is unbalanced
• When the fusible interlining is